This page displays all of the metadata information which describes this resource. This metadata information provides details of: the owners and creators of this resource; download links to any files which are available for downloading; geographical and temporal information about the datasets or project in general; other information such as a description of the project, experimental techniques used, data download restrictions, etc.
View other resources on SAFER owned/managed by the owner of this resource.
Files attached to this resource have been downloaded 48 times.
View Download Timeline Graphic
Resource or Project Abstract
In order to replicate operation of a typical domestic boiler in the laboratory, 13 boilers (6 oil-fired, 4 gas-fired and 3 wood pellet) were monitored over a heating season and the operating characteristics such as total running time, number of start-ups, typical running time during each cycle were recorded. This recorded data was then analysed to determine a suitable duty cycle for use in the laboratory and was also used to determine an appropriate emission factor that accounted for all operating modes.
Go back to top of page Top
Contact Information for This Resource
Data, Files, Information Objects Related To This Project Resource
Please Read Carefully Before Downloading
It is important for the EPA and the Environmental Research Community to know that the data and information products we distribute are useful to the user community we support. One way of doing this is by tracking the use of data and information in publications. Parts of or all of the datasets, data, or digital information products available here can be freely downloaded for further use in scientific applications under the condition that the source will be properly quoted in published papers, journals, websites, presentations, books, etc. Whenever possible the EPA strongly urge you to cite the use of these data, information, and web resources in the reference section of your publications. For convenience an automatically generated citation is available below which can be used immediately for citation purposes.
EPA SAFER Data Download Disclaimer: Before downloading any of the data or information objects below you are kindly asked to read the data download disclaimer Read Disclaimer (Opens in New Window). Downloading data or information objects from SAFER-Data indicates an acceptance of the data download disclaimer and the conditions outlined within it.
Attachment Name and Download Link |
---|
Att 1 Morrin_Gas_Boiler_Duty_cycle_analysis.xls (0.78 Mb) |
Att 2 Morrin_Oil_Boiler_Analysis_Duty_cycle_analysis.xls (1.18 Mb) |
Att 3 Morrin_Wood_Pellet_Boiler_Duty_cycle_analysis.xls (0.47 Mb) |
Suggested Citation Information
The information supplied in the table below should be provided with all citations to this electronic resource. You are requested to format each of the fields below as required by the specific bibliographical style you are using.
Author(s) | Morrin, S. |
Title Of Website | Secure Archive For Environmental Research Data |
Publication Information | Domestic Boiler Duty Cycle Measurements - Morrin UCD |
Name of Organisation | Environmental Protection Agency Ireland |
Electronic Address or URL | https://eparesearch.epa.ie/safer/resource?id=cb87971d-2997-11e1-ad3d-005056ae0019 |
Unique Identifier | cb87971d-2997-11e1-ad3d-005056ae0019 |
Date of Access | Last Updated on SAFER: 2025-01-24 |
An example of this citation in proper usage:
Morrin, S. "Domestic Boiler Duty Cycle Measurements - Morrin UCD". Associated datasets and digitial information objects connected to this resource are available at: Secure Archive For Environmental Research Data (SAFER) managed by Environmental Protection Agency Ireland https://eparesearch.epa.ie/safer/resource?id=cb87971d-2997-11e1-ad3d-005056ae0019 (Last Accessed: 2025-01-24)
Go back to top of page Top
Access Information For This Resource
SAFER-Data Display URL | https://eparesearch.epa.ie/safer/iso19115/display?isoID=251 |
Resource Keywords | domestic boiler duty cycle measurement oil gas wood pellet PM NOx emission inventory emission factor |
EPA/ERTDI/STRIVE Project Code | 2007-CCRP-4.4.2 |
EPA/ERTDI/STRIVE Project Theme | Climate Change |
Resource Availability: |
Public-Open |
Limitations on the use of this Resource | |
Number of Attached Files (Publicly and Openly Available for Download): | 3 |
Project Start Date | Thursday 1st January 2009 (01-01-2009) |
Earliest Recorded Date within any attached datasets or digital objects | Friday 30th April 2010 (30-04-2010) |
Most Recent Recorded Date within any attached datasets or digital objects | Saturday 1st May 2010 (01-05-2010) |
Published on SAFER | Sunday 18th December 2011 (18-12-2011) |
Date of Last Edit | Sunday 18th December 2011 at 16:55:57 (18-12-2011) |
Datasets or Files Updated On | Sunday 18th December 2011 at 16:55:57 (18-12-2011) |
Go back to top of page Top
Geographical and Spatial Information Related To This Resource
Description of Geographical Characteristics of This Project or Dataset
Boilers were installed at the following locations: Clane, Kildare; Donadea, Kildare; Avoca, Wicklow; Drumcondra, Dublin; Stillorgan, Dublin; Raheny, Dublin, Inchicore, Dublin and Wicklow
Flue gas temperature was recorded at 1 minute intervals over an extended period of time at 13 different locations and the resulting temperature-time trace was analysed to determine total running time, number of start-ups etc. This data was then used in the laboratory and also to derive an average emission factor that allows for all boiler operating modes
Go back to top of page Top
Supplementary Information About This Resource
In this section some supplementary information about this resource is outlined. Lineage information helps us to understand why this project was carried out, what policy or research requirements did it fulfil, etc. Lineage is important in understanding the rationale behind the carrying out of a project or the collection of a specific dataset etc. Links to web sites, applications, papers, etc are outlined to provide you with additional information or supplementary reading about the project or dataset
Lineage information about this project or dataset |
This project examined PM and NOx emissions from wood pellet, oil-fired and gas-fired domestic heating boilers, as well as non road transport. This data set contains results performed on the wood pellet boiler in a laboratory setting to determine PM and NOx emission factors as a function of boiler operating mode. Other performance factors such as efficiency, fuel consumption and operating temperatures are also available. |
Supplementary Information |
No Information Supplied For This Metadata Field By Resource Owner |
Links To Other Related Resources |
No Links To Other Web-Based Resources For This Metadata Have Been Supplied By The Resource Owner |
Any links supplied by the resource owner are stored such that they will open in a new window. Following such a link may lead to a 3rd party website over which EPA has no control in regards to contents or suitability.
Go back to top of page Top
The following is a list of similiar projects and resources on SAFER. Usually these resources share a similiar thematic area to the resource Domestic Boiler Duty Cycle Measurements - Morrin UCD you are currently viewing. You can view the full description for these projects and resources by using the links supplied.
- Potential for Negative Emissions View Full Metadata Description
- Synthesis Report: Future Targets and International Approaches to Mitigation View Full Metadata Description
- Elucidating the Impact of Aerosols on Cloud Physics and the North Atlantic Regional Climate (EIRE Climate) View Full Metadata Description
- Sourcing and Assessing Agricultural Activity Data for Modelling and National Estimates of Greenhouse Gases and Air Pollutants View Full Metadata Description
- Current Status and Required Actions for National Climate Observing Systems View Full Metadata Description
Go back to top of page Top